Ashman phenomenon

From Infogalactic: the planetary knowledge core
Jump to: navigation, search
Ashman phenomenon
File:AF with RVR-Ashmans phenomenon-RBBB aberrancy.png
Atrial fibrillation with rapid ventricular response; Ashman's phenomenon with RBBB aberrancy (13th beat)
Classification and external resources
Specialty Lua error in Module:Wikidata at line 446: attempt to index field 'wikibase' (a nil value).
eMedicine article/161028
Patient UK Ashman phenomenon
[[[d:Lua error in Module:Wikidata at line 863: attempt to index field 'wikibase' (a nil value).|edit on Wikidata]]]

Ashman phenomenon, also known as Ashman beats, describes a particular type of wide QRS complex, often seen isolated that is typically seen in atrial fibrillation. It is more often misinterpreted as a premature ventricular complex.

It is named for Dr. Richard Ashman (of New Orleans) (1890 –1969),[1] after first being described by Gouaux and Ashman in 1947.[2]

Presentation

Ashman beats are described as wide complex QRS complexes that follow a short R-R interval preceded by a long R-R interval.[3] This wide QRS complex typically has a right bundle branch block morphology and represents an aberrantly conducted complex that originates above the AV node, rather than a complex that originates in either the right or left ventricle.

Cause

It occurs because the duration of the refractory period of the myocardium is proportional to the R-R interval of the preceding cycle. A short R-R interval is associated with a shorter duration of action potential and vice versa. A long R-R cycle will prolong the ensuing refractory period, and if a shorter cycle follows, the beat terminating the cycle is likely to be conducted aberrantly. Because the refractory period of the right bundle branch is longer than the left, the right bundle will still be in the refractory period when the supraventricular impulse reaches the His-Purkinje system, resulting in a complex with right bundle branch morphology.

Prognosis

Clinically, it is often asymptomatic by itself and considered benign in nature.

References

  1. Lua error in package.lua at line 80: module 'strict' not found.
  2. Lua error in package.lua at line 80: module 'strict' not found.
  3. Lua error in package.lua at line 80: module 'strict' not found.[dead link]

Further reading

  • Lua error in package.lua at line 80: module 'strict' not found.
  • Lua error in package.lua at line 80: module 'strict' not found.
  • Lua error in package.lua at line 80: module 'strict' not found.
  • Lua error in package.lua at line 80: module 'strict' not found.
  • Lua error in package.lua at line 80: module 'strict' not found.

See also