An image dissector, also called a dissector tube, is a video camera tube in which photocathode emissions create an "electron image" which is then scanned to produce an electrical signal representing the visual image. The term may apply specifically to a dissector tube employing magnetic fields to keep the electron image in focus, and an electron multiplier to scan the electrons.[1][2] Dissectors were used only briefly in television systems before being replaced by the much more sensitive iconoscope during the 1930s.

American television pioneer Philo T. Farnsworth invented the first functional image dissector in 1927.[3][4] Earlier, German Professor Max Dieckmann and his student Rudolf Hell filed in 1925 a patent for a device named Lichtelektrische Bildzerlegerröhre für Fernseher (Photoelectric Image Dissector Tube for Television) that worked along the same principles, but failed to reduce it to practice.[3][5][6]

Operation

An image dissector focuses a visual image onto a layer of photosensitive material, such as caesium oxide, which emits negatively charged "photoelectrons" proportional to the intensity of the light striking the material. Electrostatic deflecting plates or magnetic fields then periodically manipulate the resulting electron image horizontally and vertically before an electron multiplier, or a small aperture leading to a positively charged detector or "anode" in the case of the earliest dissector tubes. The electron multiplier or aperture permits only those electrons emanating from a very small area of the electron image, representing a similarly small area of the visual image. The entire image is scanned several times per second to produce an electrical signal suitably representative of a moving visual image.[citation needed]

Because the disscector does not store charge, it is useful for viewing the inside of furnaces and monitoring welding systems as it does not suffer from the "flare" normal picture tubes experience when looking at intense lights.

History

Dieckmann and Hell submitted their application to the German patent office in April 1925, and a patent was issued in October 1927.[6] In 1951, Hell claimed that he had made a tube but could not get it to function, since at the time there was an insufficient knowledge of "electron optics", the manipulation of an electron beam by electric or magnetic fields.[3]

Farnsworth submitted a patent application for the image dissector on January 7, 1927.[4] On September 7 of that year, the image dissector successfully transmitted its first image, a simple straight line, at Farnsworth's laboratory at 202 Green Street in San Francisco.[7][8] By September 3, 1928, Farnsworth had developed the system sufficiently to hold a demonstration for the press,[8] the first such successful demonstration of a fully electronic television system.[citation needed]

In 1929 Farnsworth eliminated a motor generator from the system, so it then had no mechanical parts. Further developments that year included improvements in image clarity and an increase in the number of lines of resolution, such that it exceeded that of the mechanical television systems.[9] Also in 1929, Farnsworth transmitted the first live human images with his system, including a three and a half-inch image of his wife Elma ("Pem") with her eyes closed (possibly due to the bright lighting required).[10]

Since the electrons emitted within an image dissector are collected by the electron multiplier or anode only during the very brief time an area of the "electron image" is exposed, the bulk of the electrons are lost. Thus the earliest image dissectors were very inefficient, and extremely bright illumination was required for it to be used effectively.[citation needed] Farnsworth addressed this problem with the invention of an "electron multiplier" (not to be confused with contemporary electron multipliers), a device that increased the number of electrons in a circuit by generating "secondary emissions" of electrons from a pair of opposed surfaces, thus amplifying the electrical signal.[11]

Farnsworth applied for a patent for his "electron multiplier" on March 3, 1930 and demonstrated its application in 1931.[12][13]:137–141 Farnsworth continued to improve the device, which would come to be called a "multipactor",[14] such that it reportedly could amplify a signal to the 60th power or better,[13]:139 and showed great promise in other fields of electronics. A significant problem with the multipactor, however, was that it wore out at an unsatisfactorily rapid rate.[13]:141

On August 25, 1934, Farnsworth gave the world's first public demonstration of a complete, all-electronic television system, which included his image dissector, at the Franklin Institute in Philadelphia, Pennsylvania.[15][16]

In April 1933, Farnsworth submitted a patent application entitled Image Dissector, but which actually detailed a cathode ray tube (CRT) camera tube.[17]

By late 1930's, dissectors were replaced by more efficient iconoscopes.

References

  1. Lua error in package.lua at line 80: module 'strict' not found.
  2. Horowitz, Paul and Winfield Hill, The Art of Electronics, Second Edition, Cambridge University Press, 1989, pp. 1000-1001. ISBN 0-521-37095-7.
  3. 3.0 3.1 3.2 Lua error in package.lua at line 80: module 'strict' not found.
  4. 4.0 4.1 Farnsworth, Philo T., Television System. Patent No. 1,773,980, U. S. Patent Office, filed 1927-01-07, issued 1930-04-26. Retrieved 2010-03-12.
  5. Lua error in package.lua at line 80: module 'strict' not found.
  6. 6.0 6.1 DE 450,187, Dieckmann, Max and Rudolf Hell, "Lichtelektrische Bildzerlegerröehre für Fernseher", issued 1927-10-03, assigned to Deutsches Reich Reichspatentamt 
  7. Postman, Neil, "Philo Farnsworth", The TIME 100: Scientists & Thinkers, TIME.com, 1999-03-29, retrieved 2009-07-28.
  8. 8.0 8.1 "Philo Taylor Farnsworth (1906-1971)", The Virtual Museum of the City of San Francisco, retrieved 2009-07-15.
  9. Abramson, Albert, Zworykin, Pioneer of Television, p. 226.
  10. The Philo T. and Elma G. Farnsworth Papers, The University of Utah Marriott Library Special Collections.
  11. Farnsworth, Philo T., Electron Multiplier. Patent No. 1,969,399, U. S. Patent, filed 1930-03-03, issued 1934-08-07. Retrieved 2010-03-12.
  12. Abramson, Albert (1987), The History of Television, 1880 to 1941. Jefferson, NC: Albert Abramson. p. 148. ISBN 0-89950-284-9.
  13. 13.0 13.1 13.2 Everson, George (1949), The Story of Television, The Life of Philo T. Farnsworth New York, NY: W. W. Norton & Co,. ISBN 978-0-405-06042-7.
  14. Farnsworth, Philo T., Multipactor Phase Control. Patent No. 2,071,517, U. S. Patent Office, filed 1935-05-07, issued 1937-02-23. Retrieved 2010-03-12.
  15. "New Television System Uses 'Magnetic Lens'", Popular Mechanics, Dec. 1934, p. 838–839.
  16. Burns, R. W. Television: An international history of the formative years. (1998). IEE History of Technology Series, 22. London: IEE, p. 370. ISBN 0-85296-914-7.
  17. Farnsworth, Philo T., Image Dissector. Patent No. 2,087,683, U. S. Patent Office, filed 1933-04-26, issued 1937-07-20. Retrieved 2010-03-12.

External links

See also