Single molecule real time sequencing (SMRT) is a parallelized single molecule DNA sequencing method. Single molecule real time sequencing utilizes a zero-mode waveguide (ZMW).[1] A single DNA polymerase enzyme is affixed at the bottom of a ZMW with a single molecule of DNA as a template. The ZMW is a structure that creates an illuminated observation volume that is small enough to observe only a single nucleotide of DNA being incorporated by DNA polymerase. Each of the four DNA bases is attached to one of four different fluorescent dyes. When a nucleotide is incorporated by the DNA polymerase, the fluorescent tag is cleaved off and diffuses out of the observation area of the ZMW where its fluorescence is no longer observable. A detector detects the fluorescent signal of the nucleotide incorporation, and the base call is made according to the corresponding fluorescence of the dye.[2]

Technology

The DNA sequencing is done on a chip that contains many ZMWs. Inside each ZMW, a single active DNA polymerase with a single molecule of single stranded DNA template is immobilized to the bottom through which light can penetrate and create a visualization chamber that allows monitoring of the activity of the DNA polymerase at a single molecule level. The signal from a phospho-linked nucleotide incorporated by the DNA polymerase is detected as the DNA synthesis proceeds which results in the DNA sequencing in real time.

Phospholinked nucleotide

For each of the nucleotide bases, there are four corresponding fluorescent dye molecules that enable the detector to identify the base being incorporated by the DNA polymerase as it performs the DNA synthesis. The fluorescent dye molecule is attached to the phosphate chain of the nucleotide. When the nucleotide is incorporated by the DNA polymerase, the fluorescent dye is cleaved off with the phosphate chain as a part of a natural DNA synthesis process during which a phosphodiester bond is created to elongate the DNA chain. The cleaved fluorescent dye molecule then diffuses out of the detection volume so that the fluorescent signal is no longer detected.

Zero-mode waveguide

The zero-mode waveguide (ZMW) is a nanophotonic confinement structure that consists of a circular hole in an aluminum cladding film deposited on a clear silica substrate.[3]

The ZMW holes are ~70 nm in diameter and ~100 nm in depth. Due to the behavior of light when it travels through a small aperture, the optical field decays exponentially inside the chamber.[4]

The observation volume within an illuminated ZMW is ~20 zeptoliters (20 X 10−21 liters). Within this volume, the activity of DNA polymerase incorporating a single nucleotide can be readily detected.

Sequencing performance

Sequencing performance for the technology can be measured in read length and total throughput per experiment.

Pacific Biosciences commercialized SMRT sequencing in 2011,[5] after releasing a beta version of its instrument in late 2010.[6] At commercialization read length had a normal distribution with a mean of about 1.1 kilobases. A new chemistry kit released in early 2012 increased the sequencer's read length; an early customer of the chemistry cited mean read lengths of 2.5 to 2.9 kilobases.[7] The XL chemistry kit released in late 2012 increased average read length to more than 4.3 kilobases.[8][9] The P4 binding kit released in August 2013 combined with the XL chemistry kit yielded average read lengths to more than 5 kilobases[10] and when coupled with input DNA size selection (using an electrophoresis instrument such as BluePippin) yields average read length over 7 kilobases.[11]

Throughput per experiment for the technology is both influenced by the read length of DNA molecules sequenced as well as total multiplex of a SMRT Cell. The prototype of the SMRT Cell contained about 3000 ZMW holes that allowed parallelized DNA sequencing. At commercialization, the SMRT Cells were each patterned with 150,000 ZMW holes that were read in two sets of 75,000.[12] In April 2013, the company released a new version of the sequencer called the "PacBio RS II" that uses all 150,000 ZMW holes concurrently, doubling the throughput per experiment.[13][14] The highest throughput mode in November 2013 uses P5 binding, C3 chemistry, BluePippin size selection, and a PacBio RS II officially yields 350 megabases per SMRT Cell though a Human de novo data set released with the chemistry averaged 500 megabases per SMRT Cell. Throughput varies based on the type of sample being sequenced.[15] In September 2015, the company announced the launch of a new sequencing instrument, the Sequel System, that increased capacity to 1 million ZMW holes.[16][17]

Application

Single molecule real time sequencing may be applicable for a broad range of genomics research.

For de novo genome sequencing, read lengths from the single molecule real time sequencing are comparable to or greater than that from the Sanger sequencing method based on dideoxynucleotide chain termination. The longer read length allows de novo genome sequencing and easier genome assemblies.[18][19][20] Scientists are also using single molecule real time sequencing in hybrid assemblies for de novo genomes to combine short-read sequence data with long-read sequence data.[21][22] In 2012, several peer-reviewed publications were released demonstrating the automated finishing of bacterial genomes,[23][24] including one paper that updated the Celera Assembler with a pipeline for genome finishing using long SMRT sequencing reads.[25] In 2013, scientists estimated that long-read sequencing could be used to fully assemble and finish the majority of bacterial and archaeal genomes.[26]

The same DNA molecule can be resequenced independently by creating the circular DNA template and utilizing a strand displacing enzyme that separates the newly synthesized DNA strand from the template.[27] In August 2012, scientists from the Broad Institute published an evaluation of SMRT sequencing for SNP calling.[28]

The dynamics of polymerase can indicate whether a base is methylated.[29] Scientists demonstrated the use of single molecule real time sequencing for detecting methylation and other base modifications.[30][31][32] In 2012 a team of scientists used SMRT sequencing to generate the full methylomes of six bacteria.[33] In November 2012, scientists published a report on genome-wide methylation of an outbreak strain of E. coli.[34]

Long reads make it possible to sequence full gene isoforms, including the 5' and 3' ends. This type of sequencing is useful to capture isoforms and splice variants.[35][36]

References

  1. Lua error in package.lua at line 80: module 'strict' not found.
  2. Lua error in package.lua at line 80: module 'strict' not found.
  3. Lua error in package.lua at line 80: module 'strict' not found.
  4. Lua error in package.lua at line 80: module 'strict' not found.
  5. Lua error in package.lua at line 80: module 'strict' not found.
  6. Lua error in package.lua at line 80: module 'strict' not found.
  7. Lua error in package.lua at line 80: module 'strict' not found.
  8. Lua error in package.lua at line 80: module 'strict' not found.
  9. Lua error in package.lua at line 80: module 'strict' not found.
  10. Lua error in package.lua at line 80: module 'strict' not found.
  11. Lua error in package.lua at line 80: module 'strict' not found.
  12. Lua error in package.lua at line 80: module 'strict' not found.
  13. Lua error in package.lua at line 80: module 'strict' not found.
  14. Lua error in package.lua at line 80: module 'strict' not found.
  15. Lua error in package.lua at line 80: module 'strict' not found.
  16. http://www.bio-itworld.com/2015/9/30/pacbio-announces-sequel-sequencing-system.aspx
  17. https://www.genomeweb.com/business-news/pacbio-launches-higher-throughput-lower-cost-single-molecule-sequencing-system
  18. Lua error in package.lua at line 80: module 'strict' not found.
  19. Lua error in package.lua at line 80: module 'strict' not found.
  20. Lua error in package.lua at line 80: module 'strict' not found.
  21. Lua error in package.lua at line 80: module 'strict' not found.
  22. http://schatzlab.cshl.edu/presentations/2011-09-07.PacBio%20Users%20Meeting.pdf
  23. http://genome.cshlp.org/content/early/2012/07/24/gr.141515.112.full.pdf
  24. Lua error in package.lua at line 80: module 'strict' not found.
  25. Lua error in package.lua at line 80: module 'strict' not found.
  26. Lua error in package.lua at line 80: module 'strict' not found.
  27. http://www.nature.com/nature/journal/vaop/ncurrent/full/nature11016.html
  28. Lua error in package.lua at line 80: module 'strict' not found.
  29. http://www.nature.com/nmeth/journal/v7/n6/full/nmeth.1459.html
  30. Lua error in package.lua at line 80: module 'strict' not found.
  31. http://www.nature.com/nmeth/journal/v9/n1/full/nmeth.1779.html
  32. Lua error in package.lua at line 80: module 'strict' not found.
  33. Lua error in package.lua at line 80: module 'strict' not found.
  34. Lua error in package.lua at line 80: module 'strict' not found.
  35. http://www.nature.com/nbt/journal/v31/n11/full/nbt.2705.html
  36. http://www.pnas.org/content/early/2013/11/25/1320101110.full.pdf

External links