Supersonic wind tunnel

From Infogalactic: the planetary knowledge core
Jump to: navigation, search

Lua error in package.lua at line 80: module 'strict' not found.

Engineers check an aircraft model before a test run in the Supersonic Wind Tunnel at Lewis Flight Propulsion Laboratory.
Schlieren photography is often used to capture images of gas flow and shock waves in supersonic wind tunnels. Here, Mach 4 flow over a pitot probe is observed by schlieren optics in the Penn State Supersonic Wind Tunnel. The flow direction is left-to-right.

A supersonic wind tunnel is a wind tunnel that produces supersonic speeds (1.2<M<5) The Mach number and flow are determined by the nozzle geometry. The Reynolds number is varied by changing the density level (pressure in the settling chamber). Therefore a high pressure ratio is required (for a supersonic regime at M=4, this ratio is of the order of 10). Apart from that, condensation of moisture or even gas liquefaction can occur if the static temperature becomes cold enough. This means that a supersonic wind tunnel usually needs a drying or a pre-heating facility. A supersonic wind tunnel has a large power demand, so that most are designed for intermittent instead of continuous operation.

Restrictions for supersonic tunnel operation

Minimum required pressure ratio

Optimistic estimate: Pressure ratio \leq the total pressure ratio over normal shock at M in test section:

\frac{P_t}{P_{amb}} \leq\left(\frac{P_{t_1}}{P_{t_2}}\right)_{M_1=M_m}

Examples:

Temperature effects: condensation

Temperature in the test section:

\frac{T_m}{T_t}=\left(1+\frac{\gamma-1}{2}M_m^2\right)^{-1}

with T_t = 330 K: T_m = 70 K at M_m = 4

The velocity range is limited by reservoir temperature

Power requirements

The power required to run a supersonic wind tunnel is enormous, of the order of 50 MW per square meter of test section cross-sectional area. For this reason most wind tunnels operate intermittently using energy stored in high-pressure tanks. These wind tunnels are also called intermittent supersonic blowdown wind tunnels (of which a schematic preview is given below). Another way of achieving the huge power output is with the use of a vacuum storage tank. These tunnels are called indraft supersonic wind tunnels, and are seldom used because they are restricted to low Reynolds numbers. Some large countries have built major supersonic tunnels that run continuously; one is shown in the photo. Other problems operating a supersonic wind tunnel include:

  • starting and unstart of the test section (related to maintaining at least a minimum pressure ratio)
  • adequate supply of dry air
  • wall interference effects due to shock wave reflection and (sometimes) blockage
  • high-quality instruments capable of rapid measurements due to short run times in intermittent tunnels

Supersonic-en.svg

Tunnels such as a Ludwieg tube have short test times (usually less than one second), relatively high Reynolds number, and low power requirements.